Liquiline System CAT820은 프로세스에서 직접 샘플을 채취하기 위한 시스템으로, Memosens 기술이 적용되어 시운전이 간편하고 예측 유지보수를 지원합니다. 또한 특수한 멤브레인 표면으로 세척이 간편하고 공구 없이 유지보수할 수 있어 운영 비용이 감소합니다. CAT820을 모듈식 Flexdip 홀더와 함께 사용하면 프로세스에 맞춰 손쉽게 설치할 수 있으며, Liquiline System 분석기에 의해 제어되어 측정 개소와 완벽하게 동기화됩니다.
Liquiline System CAT820은 다음을 위해 설계되었습니다.
지자체 및 산업 폐수 처리 플랜트의 폭기조 및 배출구
지표수
산업 프로세스에서 수용액 샘플 채취
장점
Memosens 기술과 사용자 친화적인 Liquiline 작동 방식으로 신속한 시운전과 플러그 앤 플레이 지원
AVR Waste in Botlek, Rotterdam, processes up to 1.7 million tons of residual waste per year. Discover how they optimized their pH measurement thanks to Endress+Hauser
Using seawater to flush toilets can save a lot of drinking water. To ensure a constant water supply, the sensors used must function reliably to meet the water quality objectives (WQO).
Examination of wastewater, using the Liquistation CSF48 and the Liquiport CSP48 mobile, can provide valuable information about the occurrence of Covid 19 infections in a specific area
Automatic sample preparation system for supplying process measuring devices with filtered samples
Size
194 x 237 x 162 mm 7.64 x 9.33 x 6.38 in (h x w x d)
Design
Back-flush filter system with various filter mounting options: float, chain and immersion pipe Full compatibility to holder CYH112
Process temperature
4 to 40 °C (39 to 104 °F)
Ambient temperature
Unheated: 5 to 50 °C (41 to 122 °F) Heated: -20 to 50 °C (-4 to 122 °F)
Process pressure
Unpressurized
Specials
Optional back-flush with pressurizd air (version with Memosens-Technology) Controling and parametrization via Liquiline System CA80 Stand-alone version with time-control available
Application
Sampling from aeration tank and secondary clarification of municipal and industrial wastewater treatment plants Sampling of aqueous media from industrial processes
Automatic sample conditioning system for supplying process measuring
devices with filtered sample from sludge activation, secondary
clarification or surfacewater
Automatic sample conditioning system for supplying process measuring devices with filtered sample from sludge activation, secondary clarification or surfacewater
0 to 2.5 mg/l PO4-P (blue method) 0.05 to 10 mg/l PO4-P (blue method) 0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method) 0.5 to 20 mg/l PO4-P (yellow method) 0.5 to 50 mg/l PO4-P (yellow method) 0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method)
0 to 2.5 mg/l PO4-P (blue method) 0.05 to 10 mg/l PO4-P (blue method) 0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method) 0.5 to 20 mg/l PO4-P (yellow method) 0.5 to 50 mg/l PO4-P (yellow method) 0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method)