키워드, 주문 또는 제품 코드 또는 일련 번호를 검색해 보십시오(예: “CM442” 또는 “기술 정보”).
검색하려면 최소 2자 이상 입력하십시오.
product picture of the process gas analyzer S700

S700
process gas analyzer

Tailor-made gas analysis for process and emission monitoring

IS700
Please Wait (spinning wheel)
가격 로드 중
일시적으로 가격을 로드할 수 없습니다.
Price on request
가격 활성화 중
가격: 정보 제공
from CHF ??.-

사양 정보

  • Measured variables

    Ar, CBrF3, CClF3, CCl2F2, CCl3F, CHClF2, CHCl3, CH2Cl2, CH2O, CH3Cl, CH3OH, (CH3)2O, CH4, CO, CO2, CS2, C2Cl2F4, C2Cl3F3, C2Cl4, C2HCl3, C2H2, C2H2Cl2, C2H2F4, C2H3Cl3, C2H4, C2H4Cl2, C2H5OH, C2H6, C3H4, C3H6, C3H7OH, C3H8, C3H8O2, C4H6, C4H8, C4H10, C4H8O, C4H9OH, C5H12, C6H10O, C6H12, C6H14, C7H16, C7H8, C8H10, He, H2, H2O, NH3, NO, N2O, O2, SF6, SO2

  • Ambient temperature range

    +5 °C ... +45 °C

  • Hazardous area approvals

    S715 Ex:
    ATEX II 3G Ex nR IIC T6 Gc
    Without intrinsically safe measured value outputs
    ATEX II 3G Ex nR [ib] IIC T6 Gc
    With intrinsically safe measured value outputs
    S720 Ex / S721 Ex:
    ATEX II 2G Ex db ia IIC T6 Gb
    Without intrinsically safe measured value outputs
    ATEX II 2G Ex db ia [ia] IIC T6 Gb
    With intrinsically safe measured value outputs

적용 분야

With the modular gas analyzer S700, a customer-specific and tailor-made measuring device can be put together for almost every application. Various analyzer modules for the measurement of well over 60 gases, and different housing variants offer comprehensive and individually tailored combination options.

  • Cooling gas monitoring of turbo generators

  • CO measurement for coal mill monitoring

  • H2 purity measurements in pressure swing adsorption systems

  • CO2 monitoring in natural gas during natural gas processing


Device properties:

  • Various analyzer modules are available: UNOR (NDIR), MULTOR (NDIR), OXOR-E (electrochemical O2), OXOR-P (paramagnetic O2), THERMOR (thermal conductivity)

  • Over 60 measuring components to choose from

  • Different housing variants

  • Up to three analyzer modules in one housing

장점

  • Simple application-specific configuration thanks to modular design

  • Can also be used in Zone 1 and Zone 2 (ATEX) explosion-hazardous areas

  • Automatic readjustment using test gas or calibration cell

  • Integrated self-monitoring and error analysis

  • Process monitoring for the safety and quality of manufacturing processes and products by measuring flammable gases and explosive gas mixtures in zones 1 and 2

  • Reliable remote control and integration into distributed control systems thanks to optional equipment with various interface converters

Xpert 선택

  • 전문 제품

  • 까다로운 어플리케이션을 위한 설계

기술적 우수성

단순성

구성에 따라 다름

Xpert: Master your most challenging applications ©Endress+Hauser
  • 단순 제품

  • 손쉬운 선택, 설치 및 작동

기술적 우수성

단순성

  • 기본 제품

  • 신뢰성, 내구성, 유지보수가 쉬움

기술적 우수성

단순성

  • 하이엔드 제품

  • 우수한 기능성과 편리성

기술적 우수성

단순성

  • 전문 제품

  • 까다로운 어플리케이션을 위한 설계

기술적 우수성

단순성

구성에 따라 다름

FLEX 선택 기술적 우수성 단순성
  • F
  • L
  • E
  • X

Fundamental 선택

기본적인 측정 요구사항 충족

기술적 우수성
단순성
  • F
  • L
  • E
  • X

Lean 선택

핵심 프로세스를 손쉽게 처리

기술적 우수성
단순성
  • F
  • L
  • E
  • X

Extended 선택

혁신적인 기술로 프로세스 최적화

기술적 우수성
단순성
  • F
  • L
  • E
  • X

Xpert 선택

가장 까다로운 어플리케이션 요구사항 충족

기술적 우수성
단순성

구성에 따라 다름

Please Wait (spinning wheel) Loading alternative products