US style metrical modular temperature assembly for heavy duty applications suitable for hazardous areas to use with thermowell backlit display
Thermowell / protection tube
to be used with thermowell
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
Insert Diameter 6,0 mm (0,24'')
Max. immersion length on request
Not defined
Material protection tube/ thermowell
Not defined
Optional coating
Not defined
Process connection
Thermowell connection male thread: G1/2" NPT1/2" NPT3/4" cap nut: NPT1/2" M24x1.5
Tip shape
Not defined
Surface roughness Ra
Not defined
Operating temperature range
PT 100: -200 °C ...600 °C (-328 °F ... 1.112 °F)
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
Accuracy
class A acc. to IEC 60751 class AA acc. to IEC 60751
Response time
depending on configuration t50 = 4 s t90 = 8 s
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
general purpose ATEX II1G Ex ia IIC T6 ATEX II2G Ex d IIC T6, II2D ATEX Ex d, Ex ia ATEX II 3G EEx nA IIC T4/T5/T6 ATEX II1/2G Ex d IIC T6, II1/2D ATEX Ex d, Ex ia ATEX II1G Ex ia IIC T6 ATEX II2G Ex d IIC T6, II2D ATEX II1/2G Ex d IIC T6, II1/2D ATEX II1/2G Ex ia IIC T6, II1/2D Ex EAC Ga/Gb Ex ia IIC, Ex ia IIIC Da/Db EAC Ga/Gb Ex d IIC, Ex ta/tb IIIC Da/Db EAC Ga/Gb Ex ia IIC, Ex ia IIIC Da/Db EAC Ga/Gb Ex d IIC, Ex ta/tb IIIC Da/Db Explosion proof